Description

HI708 Details:

Ideal for marine, salt and fresh water aquariums, along with environmental, water quality and wastewater testing.

The HI-708 Checker is a simple, accurate, and cost effective way to measure high ranges of nitrite.

  •  0 to 150ppm
  •  Ideal for aquariums
  •  Nitrite

Ideal for marine, salt and fresh water aquariums

The HI-708 Checker is a simple, accurate, and cost effective way to measure high ranges of nitrite

Designed as a more accurate alternative to chemical test kits, the HI 708 provides quick, accurate results in four easy steps (see below).

The HI-708 uses an adaptation of the Ferrous Sulphate method. The reaction between nitrite and the reagent causes a greenish/brown tint in the sample.

Also ideal for:

  • Water Quality
  • Education
  • Aquariums (marine, salt and fresh water)
  • Wastewater
  • Environmental

Features:

  • Small palm-sized design
  • Accurate from ±3 ppm ±5% of reading
  • Dedicated to a single parameter
  • Uses a single AAA battery
  • Auto Power Off after 10 minutes in inactivity
  • Built-in timer for timed reaction readings

Order Information:

The HI-708 Checker is supplied with:

  • 2 cuvettes and caps
  • reagent starter kit (6 packets of reagent) - re-ordering information HI-708-25
  • 1 X 1.5X AAA battery
  • Instruction manual

Aquarium use

The checker is useful for initial measurements of nitrite when trying to establish good ammonia/nitrite/nitrate control. Suitable for all types of aquaculture, the ultimate aim is to decrease nitrite levels so that the low range of ultra-range nitrite checker can be used for optimum tank health.

Nitrite can lead to tissue damage, illness and death of aquatic life, so regular checks can help aquarists identify rising nitrite levels before fish begin to suffer.

Four steps. One click. Instant Readout.

Step 1  1. ‘Zero’ the Checker®HC with your vial & 10ml water sample inside

Step 2  2. Take the vial out and add your reagent

Step 3  3. Place your vial into your Checker®HC

Step 4  4. Press the button and read the results

 

Use Calibration Check Set HI-708-11 with the HI-708 Nitrite High Range Checker®HC.

Use reagents HI-708-25 with the HI-708 Nitrite High Range Checker®HC, 25 tests.

Range   0 to 150 ppm
Resolution   1 ppm
Accuracy @ 25°C   ±3 ppm ±5% of reading
Light source   LED @ 575 nm
Light Detector   Silicon photocell
Method   Adaptation of the Ferrous Sulphate method
Environment   0 to 50°C; RH max 95% non-condensing
Battery Type   (1) 1.5V AAA
Auto-off   After ten minutes of non-use
Dimensions   81.5mm x 61mm x 37.5mm
Weight   64g
Ordering Information   HI-708 Checker® is supplied with (2) sample cuvettes with caps, nitrite HR reagent starter kit for 6 tests (6 powder reagent packets), battery, instructions and quick start guide.

HI708-11 Details:

The Nitrite High Range Checker® HC Calibration Check Set – HI-708-11 provides a simple solution to validating the Nitrite High Range Checker® HC – HI-708 in the range of 0 to 150 ppm (mg/L) nitrite. 

HI-708-11 is a high-quality set of calibration standards that allows users to validate the Nitrite High Range Checker® HC – HI-708. The HI-708-11 includes one sealed cuvette for zero ppm nitrite and one cuvette that is tinted to an equivalent 75 +/- 5 ppm nitrite sample @ 25°C. The calibration check set is produced using reagent grade chemicals in a temperature controlled environment.

HI708-25 Details:

The HI-708-25 are the replacement reagents for the HI-708 Nitrite High Range Checker® HC.

  •  25 tests

hese high-quality reagents are clearly marked with the lot number and expiry date on each packet for traceability.

The HI-708-25 are high-quality reagents that are pre-measured, allowing for users to achieve fast and accurate measurements with their Nitrite High Range Checker® HC. These reagents follow the Ferrous Sulphate Method in which the reaction between nitrite and reagent causes a greenish-brown tint in the sample. By simply adding the packet of HI-708-25 reagent to the sample, the reaction will take place and the HI-708 will determine the concentration from the colour that is produced. The results will be displayed in ppm (mg/L) of nitrite. These reagents are designed to be used with samples that have an expected range of 0 to 150 ppm nitrite.

Tip for an accurate measurement

It is important that the sample does not contain any debris.

Whenever the cuvette is placed into the measurement cell, it must be dry outside and completely free of fingerprints, oil or dirt. Wipe it thoroughly with HI-731318 or a lint-free cloth prior to insertion.

Shaking the cuvette can generate bubbles, causing higher readings. To obtain accurate measurements, remove such bubbles by swirling or by gently tapping the cuvette.

Do not let the reacted sample stand for too long after reagent is added, or accuracy will be lost.

After the reading, it is important to discard the sample immediately, otherwise the glass might become permanently stained.

Four steps. One click. Instant Readout.

1. ‘Zero’ the Checker®HC with your vial inside

2. Place a 10ml water sample into the vial and add your reagent

3. Place your vial into your Checker®HC

4. Press the button and read the results

Also available: HI-708-11 calibration set.

Package   sachets
Quantity   25 tests
Method   Adaptation of the Ferrous Sulphate method. The reaction between nitrite and the reagent causes a greenish-brown tint in the sample.

 

Specifications

Icons meaning

Documents

Lorem ipsum dolor sit amet, consectetur adipisicing elit. Ab blanditiis commodi earum error exercitationem fuga harum, id illo itaque labore minima molestiae molestias praesentium quasi quidem quisquam ratione repellendus velit.

Documents

Lorem ipsum dolor sit amet, consectetur adipisicing elit. Ab blanditiis commodi earum error exercitationem fuga harum, id illo itaque labore minima molestiae molestias praesentium quasi quidem quisquam ratione repellendus velit.

Documents

Lorem ipsum dolor sit amet, consectetur adipisicing elit. Ab blanditiis commodi earum error exercitationem fuga harum, id illo itaque labore minima molestiae molestias praesentium quasi quidem quisquam ratione repellendus velit.

More Information
Home popularNo
Featured ProductsNo
SaleNo
NewNo
Exclude from downloadable listsNo
Product Needs to appear in the sale widgetNo
Child has discount0
BrandHanna
SizeN/A
Species typeChecker photometer for nitrite HR (0-150 ppm)