Checker photometer for fluoride LR

Checker photometer for fluoride LR with starter kit reagents - HANNA-HI729
Size S/M
Out of stock
Kit with standards for HI729 - HANNA-HI729-11
Size S
Out of stock
Reagents for Fluoride LR, Approx: 25 pcs - HANNA-HI729-26
Size S
Out of stock
Description

HI729-11 Details:

The HI-729 Checker® HC (Handheld Colorimeter) provides a simple, accurate and cost-effective way to measure fluoride.

Fluoride is one of the few chemicals that have been shown to cause significant effects in people through drinking water. Fluoride has beneficial effects on teeth at low concentrations in drinking water, but excessive exposure to fluoride in drinking water, or in combination with exposure to fluoride from other sources, can give rise to a number of adverse effects.

The HI-729 pocket checker is a simple and accurate way to measure low ranges of fluoride.

Water fluoridation is the controlled addition of fluoride to a public water supply to reduce tooth decay. Fluoridated water operates on tooth surfaces: in the mouth it creates low levels of fluoride in saliva which reduces the rate at which tooth enamel de-mineralises and increases the rate at which it re-mineralises in the early stages of cavities.

A 1994 World Health Organisation expert committee suggested a level of fluoride from 0.5 to 1.0 mg/L, depending on climate. Bottled water typically has unknown fluoride levels, and some domestic water filters remove some or all fluoride.

Key features

  • Accurate and easy to use
  • Adaptation of SPADNS method
  • ±0.05 ppm ±5% of reading
  • 0.01 ppm resolution
  • Designed to work with Hanna reagents
  • Large easy to read digits
  • Auto shut-off

Ideal for

  • Water testing
  • Quick on the spot analysis

Supplied with

  • 2 sample cuvettes with caps
  • Reagents for 6 tests (re-ordering information HI-729-26 x 20 tests
  • Syringe with tip
  • 1 x 1.5V AAA battery
  • Instructions

Four steps. One click. Instant Readout.

Step 1  1. ‘Zero’ the Checker®HC with your vial inside

Step 2  2. Place a 10ml water sample into the vial and add your reagent

Step 3  3. Place your vial into your Checker®HC

Step 4  4. Press the button and read the results

 

Use Calibration Check Set HI-729-11 with the Hi-729 Fluoride Low Range Handheld Colorimeter, Checker®HC.

Use reagent HI-729-26 with the Hi-729 Fluoride Low Range Handheld Colorimeter, Checker®HC, x 20 tests.

Range   0.00 to 2.00 ppm
Resolution   0.01 ppm
Accuracy @ 20°C   ±0.05 ppm ±5% of reading
Light Source   LED @ 575 nm
Light Detector   silicon photocell
Environment   0 to 50°C (32 to 122°F); RH max 95% non-condensing
Battery Type   (1) 1.5V AAA
Auto-off   after two minutes of non-use and ten seconds after reading
Dimensions   81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
Weight   64 g (2.25 oz.)
Method   adaptation of SPADNS method

HI729-11 Details:

The Fluoride Low Range Checker® HC Calibration Check Set – HI-729-11 provides a simple solution to validating the calibration of the Fluoride Low Range Checker ® HC – HI-729 that has a range of 0.00 to 2.00 ppm (mg/L). 

Hanna optional Checker HC Calibration Sets provide a simple solution to validating your Checker HC. Each high quality set of standards is manufactured in our state-of-the-art facility and comes supplied with a Certificate of Analysis. The certificate of Analysis provides the lot number, reference values and expiry date to provide traceability when certifying the Checker HC.

HI-729-11 is a high-quality set of standards that allows users to validate the Fluoride Low Range Checker ® HC – HI-729 calibration. The HI-729-11 includes one sealed cuvette for zero ppm fluoride and one cuvette that is tinted to an equivalent 1.00 +/- 0.10 ppm fluoride sample @ 25°C. The calibration check set is produced using reagent grade chemicals in a temperature controlled environment.

HI729-26 Details:

These high-quality reagents are clearly marked with the lot number and expiry date on the bottle for traceability.

The HI-729-26 are high-quality reagents that are pre-measured, allowing for users to achieve fast and accurate measurements with their Fluoride Low Range Checker® HC. These reagents follow the SPADNS Method in which the reaction between fluoride and the reagent causes a colourless complex in the sample. By simply adding 2 mL of SPADNS reagent to two cuvettes, and subsequently 8 mL of deionised water to one and 8 mL of sample in the other, the reaction will take place and the HI-729 will determine the concentration from the colour that is produced. The results will be displayed in ppm of fluoride. These reagents are designed to be used with samples that have an expected range of 0.00 to 2.00 ppm (mg/L) fluoride.

Specifications

Icons meaning

Documents

Lorem ipsum dolor sit amet, consectetur adipisicing elit. Ab blanditiis commodi earum error exercitationem fuga harum, id illo itaque labore minima molestiae molestias praesentium quasi quidem quisquam ratione repellendus velit.

Documents

Lorem ipsum dolor sit amet, consectetur adipisicing elit. Ab blanditiis commodi earum error exercitationem fuga harum, id illo itaque labore minima molestiae molestias praesentium quasi quidem quisquam ratione repellendus velit.

Documents

Lorem ipsum dolor sit amet, consectetur adipisicing elit. Ab blanditiis commodi earum error exercitationem fuga harum, id illo itaque labore minima molestiae molestias praesentium quasi quidem quisquam ratione repellendus velit.

More Information
Home popularNo
Featured ProductsNo
SaleNo
NewNo
Exclude from downloadable listsNo
Product Needs to appear in the sale widgetNo
Child has discount0
BrandHanna
SizeS/M
Species typeChecker photometer for fluoride LR