Magnesium HR Checker
HI719 Details:
Ideal for wastewater, the HI-719 pocket checker is a simple and accurate way to measure magnesium hardness.Checker®HC is supplied with reagents for 25 tests. Use code HI-719-25 (25 tests) for future purchases.
- 0.00 to 2.00 ppm range
- Ideal for wastewater
The HI-719 pocket checker is a simple and accurate way to measure magnesium hardness.
The HI-719 uses an adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, EDTA colorimetric method. The reaction between magnesium and reagents causes a reddish violet tint in the sample.
Key features
- Accurate and easy to use
- ±0.20 ppm ±5% of reading
- 0.01 ppm resolution
- Designed to work with Hanna reagents
- Large easy to read digits
- Auto shut-off
Ideal for
- Water purification systems
- Heating and cooling systems
- Drinking water
- Wastewater
Supplied with
- 2 sample cuvettes with caps
- Reagents for 25 tests (re-ordering information HI-719-25 x 25 tests)
- Syringe with tip
- Plastic beaker
- 1 x 1.5V AAA battery
- Instructions
Also available: Calibration set HI-719-11.
Four steps. One click. Instant Readout.
1. ‘Zero’ the Checker®HC with your vial & water sample inside
2. Take the vial out and add your reagent
3. Place your vial into your Checker®HC
4. Press the button and read the results
Use HI-719-25 Reagents with Hi-719 Magnesium Hardness Handheld Colorimeter - Checker®HC - 25 tests.
Use HI-719-11 Calibration Check Set with Hi-719 Magnesium Hardness Handheld Colorimeter - Checker®HC.
| Range | 0.00 to 2.0 ppm | |
| Resolution | 0.01 | |
| Accuracy @ 25°C | ±5% of reading ±0.20ppm | |
| Light source | LED @ 525 nm | |
| Light Detector | Silicon photocell | |
| Method | Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, EDTA colorimetric method. The reaction between magnesium and reagents causes a reddish-violet tint in the sample. | |
| Environment | 0 to 50°C; RH max 95% non-condensing | |
| Battery Type | (1) 1.5V AAA | |
| Auto-off | After ten minutes of non-use | |
| Dimensions | 86.0mm x 61.0mm x 37.5mm | |
| Weight | 64g | |
| Ordering Information | HI-719 Checker® is supplied with (2) sample cuvettes with caps, reagent starter kit x 25 tests (re-ordering HI-719-25 x 25 tests), 1 x 1.5 AAA battery, instructions. |
HI719-11 Details:
The Magnesium Hardness Checker® HC Calibration Check Set – HI-719-11 provides a simple solution to validating the Magnesium Hardness Checker® HC – HI-719. This high-quality set of standards is supplied with a Certificate of Analysis.
HI-719-11 is a high-quality set of calibration standards that allows users to validate the Magnesium Hardness Checker®HC – HI-719. The HI-719-11 includes one sealed cuvette for zero ppm CaCO3 and one cuvette that is tinted to an equivalent 1.00 ± 0.20 ppm CaCO3sample @ 25°C. The calibration check set is produced using reagent grade chemicals in a temperature controlled environment.
HI719-25 Details:
The HI-719-25 are the replacement reagents for the HI-719 Magnesium Hardness Checker® HC. These high-quality reagents are clearly marked with the lot number and expiry date on each packet for traceability.
- Hardness
- 25 tests
The HI-719-25 are high-quality reagents that are pre-measured, allowing for users to achieve fast and accurate measurements with their Magnesium Hardness Checker® HC. These reagents follow the EDTA colorimetric method in which the reaction between magnesium and the reagent causes a violet tint in the sample. When the HI-719-25 reagents are added to the sample, the reaction will take place and the HI-719 will determine the concentration from the colour that is produced. The results will be displayed in ppm of magnesium hardness as CaCO3. These reagents are designed to be used with samples that have an expected range of 0.00 to 2.00 ppm CaCO3.
Tip for an accurate measurement
It is important that the sample does not contain any debris.
Whenever the cuvette is placed into the measurement cell, it must be dry outside and completely free of fingerprints, oil or dirt. Wipe it thoroughly with HI-731318 or a lint-free cloth prior to insertion.
Shaking the cuvette can generate bubbles, causing higher readings. To obtain accurate measurements, remove such bubbles by swirling or by gently tapping the cuvette.
Do not let the reacted sample stand for too long after reagent is added, or accuracy will be lost.
After the reading, it is important to discard the sample immediately, otherwise the glass might become permanently stained.
Icons meaning
Documents
Lorem ipsum dolor sit amet, consectetur adipisicing elit. Ab blanditiis commodi earum error exercitationem fuga harum, id illo itaque labore minima molestiae molestias praesentium quasi quidem quisquam ratione repellendus velit.
Documents
Lorem ipsum dolor sit amet, consectetur adipisicing elit. Ab blanditiis commodi earum error exercitationem fuga harum, id illo itaque labore minima molestiae molestias praesentium quasi quidem quisquam ratione repellendus velit.
Documents
Lorem ipsum dolor sit amet, consectetur adipisicing elit. Ab blanditiis commodi earum error exercitationem fuga harum, id illo itaque labore minima molestiae molestias praesentium quasi quidem quisquam ratione repellendus velit.
| Home popular | No |
|---|---|
| Featured Products | No |
| Sale | No |
| New | No |
| Exclude from downloadable lists | No |
| Product Needs to appear in the sale widget | No |
| Child has discount | 0 |
| Brand | Hanna |
| Size | S/M |
| Species type | Magnesium HR Checker |

Tank Bred
Cultured corals
Marine Fish
Soft Corals
LPS Corals
SPS Corals
Inverts
Rocks
Products
New arrivals
Outlet
Special offer